Hematology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow An erratum has been published
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dzik, W. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dzik, W. H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hematology 2005
© 2005 The American Society of Hematology

Technology for Enhanced Transfusion Safety

Walter H. Dzik

Correspondence: Walter H. Dzik, MD, Massachusetts General Hospital, Room J-224, 55 Fruit Street, Boston MA 02114; Phone: (617) 726-3715, Fax: (617) 726-6832, sdzik{at}partners.org

Abstract

Data from reporting systems around the world document that non-infectious hazards are the leading cause of serious morbidity or mortality resulting from blood transfusion. Among these non-infectious hazards, mis-transfusion represents the most frequently observed serious hazard and occurs at an estimated rate of 1 in 14,000 transfusions. Mis-transfusion events result from "lapse errors" (slip ups) rather than cognitive mistakes. Lapse errors are more likely to occur during repetitive tasks when individuals are distracted, rushed, or fatigued—conditions to which machines are not susceptible. The final bedside check and the collection of patient samples for pre-transfusion testing are key "error spots" and are candidates for new technology innovation. Existing technology includes non-computerized devices; bedside devices based on bar code technology; and the use of radiofrequency chips. Several commercial systems employing bar-code technology have reached clinical application or are undergoing refinement. Radiofrequency-based systems are on the near horizon. Nearly all systems begin with the application of machine-readable data to the patient’s wristband. The third error spot—the decision to transfuse—will be a challenging area for future application of information technology. Computerized physician order-entry, decision support and ultimately active computer-based decision-making are expected to enhance transfusion decisions. Despite the explosive growth in information technology in modern society, healthcare has lagged behind many other sectors in the use of enhanced information technology. Studies are needed to identify which technologies improve patient outcomes. Healthcare workers, administrators, and regulators need to embrace the use of new technology in order to reduce errors and improve safety for patients.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the American Society of Hematology.